A NSW rental check. It meets the NSW rules, with good-practice upgrades listed separately so the agent knows what's law and what's advice.

An example with made-up details. Yours fill in from the job, with your business, licence and logo.

Smoke alarm certificate

8 Sample Avenue, Tweed Heads NSW 2485

SA-0016 · New lease or renewal · New South Wales · checked 8 October 2026

Based on the alarms recorded and tested by Sam Sparky on 8 October 2026, they met the New South Wales smoke alarm requirements listed below.

Recommended

Good practice and other New South Wales rules to know. These don't count against this certificate.

  • Alarms 1 and 2: not interconnected. Interconnected alarms are recommended.
  • Alarm 2: not photoelectric. Photoelectric alarms are recommended.
  • Alarm 2: removable battery only. Hardwired or a 10-year sealed battery is recommended.
  • 3 bedrooms but 0 bedroom alarms. An alarm in every bedroom is recommended.
  • The landlord checks the alarms every year and replaces removable batteries every year.
  • Hardwired alarms may only be repaired or replaced by a licensed electrician.
  • Rental alarms are replaced within 10 years of manufacture (sooner if the maker says).
Storeys
1
Bedrooms
3
Hallways and exit paths
Confirmed covered by the person checking
Checked by
Sam Sparky
Business
Example Electrical
Electrical licence
00000
Contact
0400 000 000 · hello@example.com
Next check due
8 October 2027

Alarms (2)

  1. 1. Hall outside bedrooms

    10-year sealed battery · Photoelectric Yes · AS 3786 Yes · Interconnected No

    Test: Pass · Tested and cleaned · Replace by 2033-03

  2. 2. Living room

    Removable battery only · Photoelectric No · AS 3786 Yes · Interconnected No

    Test: Pass · Battery replaced · Replace by 2029-08

Requirements checked: alarms to AS 3786; an alarm on every storey; hallways between the bedrooms and the rest of the home, as confirmed by the person checking; not past the replace-by date shown on the alarm. Each alarm was tested with its test button.

Checked against: Environmental Planning and Assessment (Development Certification and Fire Safety) Regulation 2021 (NSW), Part 13 Div 2; Residential Tenancies Act 2010 and Residential Tenancies Regulation 2019 (rentals).

Not assessed: exact placement (distances from walls, corners, lights, fans, vents and stairs) and the wiring behind the alarms. This records the alarms as found and recorded on the day.